Icom a2 ISTA P V3 58 with BMW F10 programming solution
Icom a2 ISTA P V3 58 with BMW F10 programming solution
Have used2016 Ista P version 3.58 to do some programming on F10 but always got the error message:
an error occurred on execution of the measure.
94201 technical service initialisation failed
-2 global unknown
63014 (castor) - error when executing a psdz function
63014 (castor) - error when executing a psdz function

Ediabas 7.3.0 is installed correctly and patched. There is no problem with other cars like E series.
Windows Firewall is disabled and there is no other security software on that laptop.
ISTA/P works OK with other cars, so presume configuration is OK.
Reset a batteryon the vehicle. It is said that if F series sometimes gives this error, disconnecting the battery for 15 minutes usually solves the problem...but not worked for me also.
I installed the BMW software myself and I am not any expert on the matter, so it is possible I have copied some files into wrong directories. I have two main folder on C: drive Rheingold with ISTA Diagnosis which works well. My SQliteDBs and PSdZ folders are in there. ISTA P is installed in a separate folder on C: drive . There is no PSdz subfolder in ISTA P.Then i copied data to the following directory:%:ISTA-PBMWServicesdataecudata...not worked too
Finally, i guessed it was related to the faulty ICOM A1. So i connected the different BMW Icom A2 emulator from a Chinese vendor: diyobd2.fr, the problem has gone ....
Available link for download
Saturday, February 4, 2017
solved ICOM NEXT ISTA P error occurred during execution
solved ICOM NEXT ISTA P error occurred during execution
Used ISTA / P 3.60.1 (Loader 6.1F) with ICOM NEXT for bmw motorcycle programming but met the error message:
Fehler
Bei der Durchfuhrung der MaBnahme ist ein Fehler aufgetreten
94201 Fachdiendtinitialisierung fhelgeschlagen
-2 Global Unknown
1000000 Global Unknown


(Error in ISTA P
An error occurred during the execution of the action
94201 Technical deadline initialization fhelgeschlagen
-2 Global Unknown
1000000 Global Unknown)
Here is the customer solution:
Try to disconnect the battery for 15 min.
then reconnect the battery
turn ignition on (KL:15)
wait 1min and then connect the ICOM and restart
then reconnect the battery
turn ignition on (KL:15)
wait 1min and then connect the ICOM and restart
On a note from another:
There is not enough info to determine which model the programming is being attempted on but the belief that disconnecting battery on the the bikes does some form of reset on engine ECU is an urban myth, power is removed from the processor systems and memory every time the ignition is turned off
I will try and report here. Hope it does help.